FATCAT: Fault Injection Attacks Targeting Chip-level Alignment

One electromagnetic pulse at the GPU chip can bypass a language model's refusals, or make a robot arm lunge.

Peter Horvath1 Ilia Shumailov Zhuoran Liu2 Łukasz Chmielewski3 Lejla Batina1

1Radboud University 2University of Amsterdam 3Masaryk University

TL;DR

We bypass the safeguards of AI models by faulting the hardware that runs them. A single electromagnetic pulse injected into an NVIDIA Jetson is enough.

Language model (LLM)

Fired while the model loads, the pulse cuts the refusal rate of Llama 3.2 1B on harmful prompts from 98% to 23–35%.

Robot policy (VLA)

Fired at a Jetson that runs a SmolVLA policy, the pulse makes the robot arm lunge at its operator.

Only 23–35%

of harmful prompts refused by Llama 3.2 1B, after one pulse while the weights load.

Up to 97%

of the prompts yield an unsafe answer under pulses during inference.

119–359°

change in the planned motion of a robot arm after a single pulse.

01
The attack

How the attack works

Safety evaluations test prompts and weights, and assume that the hardware computes correctly.

On an edge device or a robot, an attacker can get close to that chip. Our experiments use laboratory equipment, but a setup based on the open-source FaultyCat costs under $1,000. The attacker needs no code execution and no credentials.

A pulse generator over the edge chip, with two branches. Upper branch: a cracked shield around the robot's policy, then a robot arm swinging towards a worker. Lower branch: a language model with its refusal layer wiped, then a chat in which a harmful request is answered.

Listen

A near-field probe over the chip detects when a prompt starts to run, and this triggers the pulse.

Pulse

After a set delay, a pulse hits the memory interface of the chip, or the LPDDR package next to it.

Corrupt memory

The memory is encrypted, so one faulted transfer turns a 16-byte block of weights or activations into random data.

02
Setup

The setup on the Jetson AGX Thor

We remove the heatsink and place the injection probe over one of two targets.

The persistent and the transient faults in the next two sections share these setups.

Target 1LPDDR PHY

Photo of the lab setup: oscilloscope, pulse generator, positioning stage and the Jetson Thor board with a probe over its chip
Setup on the Jetson AGX Thor with the LPDDR PHY of the SoC as the injection target.

Target 2LPDDR package

Close-up of the Jetson AGX Thor board. The EM injection probe sits over the LPDDR package, and the near-field probe sits over the exposed NVIDIA SoC die.
The same setup (oscilloscope, pulse generator, etc.), but with a different injection probe over the LPDDR package.
03
Persistent faults

One pulse to rule them all

Inference frameworks do not check weights once they are in memory. A fault during loading therefore stays for every later prompt.

A single pulse can corrupt the scale of one tensor, which removes that tensor from the model. This more than halves the refusal rate on Llama and roughly halves it on Gemma, and for the best tensors the MMLU score is almost unchanged.

The prompts are the 100 harmful behaviours of JailbreakBench, and DeepSeek V4.1 Flash labels the answers. On Llama, the same wipe of layer 11 leaves a refusal rate of 23–35%, depending on the boot. The chart shows one of them.

Answers to 100 harmful prompts after a wipe

Refused Unsafe Vague or garbled ★Best trade-off MMLU
04
Transient faults

Inference time transient faults

A pulse while a prompt runs corrupts one layer as it passes through the memory interface. The stored weights stay as they were.

We send each of the 100 harmful prompts 15 or 50 times, with a pulse aimed at the layers that carry the refusal behaviour. The prompts and the judge are the same as above.

Prompts with at least one bypass

Unsafe answer Refusal bypassed

Over repeated attempts, up to 97% of the prompts yield an unsafe answer, reached by Llama 3.2 1B on the Orin Nano.

05
Robot arm

Faulting a real robot

A vision-language-action policy turns camera images directly into motor commands, so a fault in the policy directly changes the motion.

We pulse a Jetson Orin Nano that runs a SmolVLA policy and drives a robot arm. We fault only the model, not the cameras or the arm.

Side cameraSide camera view: the robot arm at rest on a white table, with a red cube in front of it and a plastic box next to it
Top cameraTop camera view of the same scene: the arm, the red cube and the plastic box seen from above
The two camera views that the policy gets, with the arm at rest. Its task is to pick up the red cube and place it in the box.

Some pulses during inference gave plans that differ from the fault-free plan by 119–359°, and the arm carried them out. A pulse while the policy loads corrupts weights that are read at every step, so the arm stays erratic until the policy is shut down. The clips are in the next section.

0.00 sA hand reaches into the box next to the resting robot armOperator reaches in
+0.36 sThe robot arm rears upThe arm rears up
+0.56 sThe robot arm lunges at the handLunges at the hand
06
Clips

Experiments on video

We show clips of some of the experiments here and they are also on YouTube.

VLARobot arm

Normal vs. lunging robot armLeft: the arm in normal operation. Right: the arm has placed the cube in the box and is returning to its rest pose. As the operator reaches into the box, a single pulse during inference corrupts one plan: the arm rears up and lunges at the hand in about half a second.
Persistent fault-injection end-to-end experimentAn attack to achieve a persistent fault in the weights of the model. The 25th pulse, less than six minutes in, garbles one block in layer 7, and the arm then runs the faulted policy erratically for two minutes.
Disabling robot arm via EMFIThe arm picks up the cube and carries it to the box. A pulse then stops it, and it stays still for the rest of the clip. In the background, the pulse injector is held by hand over the Jetson. The injector only costs $120.

LLMLanguage models on the Jetson AGX Thor

All three are experiments with the injection probe over the LPDDR package.

Llama 3.2 1B, layer 8A sped-up replay of a whole run: 100 harmful prompts from JailbreakBench, 20 attempts each, with one pulse per answer aimed at layer 8. On the left is the probe trace with the pulse, on the right the answer and the verdicts of two LLM judges. For 26 of the 100 prompts, at least one answer is harmful according to both judges.
Llama 3.2 1B, layer 7The same experiment with the pulse aimed at layer 7. For 18 of the 100 prompts, at least one answer is harmful according to both judges.
Gemma 3 1BThe same experiment on Gemma 3 1B, with the pulse aimed at layer 9. For 31 of the 100 prompts, at least one answer is harmful according to both judges.
07
Future work

Future work

We barely scratched the surface of what is possible.

Fixing timing

A recurring theme in our experiments is the very imprecise timing of the fault injection. As soon as this is fixed, we expect the number of required trials to go down significantly for both the robot arm and the jailbreak experiments.

Theoretical analysis

More theoretical work could be done on the interaction of different random faults in a model. We only explored the impact of a single fault in a single tensor. While this single fault can already be very impactful, an attacker is not limited to a single fault.

It would also be interesting to see what the best strategy for an attacker is. Generally, they either want the model to comply with a particular request, or want a still highly functional model. We believe devising different strategies based on the specific goal of an attacker is worth exploring.

08
Cite

BibTeX

To cite the paper, please use:

@misc{horvath2026fatcat,
  title  = {{FATCAT}: Fault Injection Attacks Targeting Chip-level Alignment},
  author = {Horvath, Peter and Shumailov, Ilia and Liu, Zhuoran and
            Chmielewski, {\L}ukasz and Batina, Lejla},
  year   = {2026},
  eprint = {2611.31129},
  archivePrefix = {arXiv},
  primaryClass  = {cs.CR},
  url    = {https://arxiv.org/abs/2611.31129}
}